Checking events generated by the user life-cycle commands 

View traces in the log files to get information about the user life-cycle commands that are sent from Profiles to the other IBM Connections applications.


About this task

User life-cycle commands are built on top of the event infrastructure. When an update is made to a user using one of the life-cycle commands, a message is sent over the event infrastructure from Profiles to the other applications.


Procedure

To check that the user life-cycle commands are being sent from Profiles to the other applications...

  1. Enable trace logging for the com.ibm.lconn.lconn.events process in the WAS.

      For information about how to enable trace logging, see Enable traces in WAS.

  2. Check the log files for information relating to events.

      Log entries relating to the user life-cycle commands that are sent from Profiles to the other applications are identified with the prefix, com.ibm.lconn.events.*.

      When a user is updated, a message is sent over the event infrastructure to other applications, and the log looks similar to the following.

       [28/04/10 19:01:24:053 IST] 00000032 JMSPublisher 3 com.ibm.lconn.events.internal.publish.impl.JMSPublisher publishEvent
      ***************
      Event data
      ***************
      _er_id: 26c21157-4d43-4534-ad07-d44f86832c91
      _er_time: 1272477684021
      _er_source: PROFILES
      _er_type: COMMAND
      _er_name: user.record.update
      _er_scope: PUBLIC
      _er_related_community: null
      _er_actor: null
      _er_actor_name: null
      _er_actor_email: null
      _er_properties: {"updated_directoryid":"S-1-401595654-2584217272-3161732908-1084554606-880431025-3930541184","_msg_id":"0","updated_email":"ajones141@example.com","directoryid":"S-1-401595654-2584217272-3161732908-1084554606-880431025-3930541184","updated_logins":" [\"ajones141\",\"ajones141@example.com\"]","updated_name":"Updated Sample Name"}
       
      Container:
      _er_container_id: null
      _er_container_name: null
      _er_container_html_path: null
       
      Item:
      _er_item_id: null
      _er_item_name: null
      _er_item_html_path: null
      _er_item_atom_path: null
      ***************
       

      The example above shows the update that was triggered when the following command was issued:

      ProfilesService.updateUser("ajones141@example.com", displayName="Updated Sample Name")


Parent topic

Troubleshooting user data propagation


Related tasks


Enable traces in WAS


   

 

});

+